Used enterprise gear is the best value in homelab. It also comes with someone else's settings, someone else's firmware, and sometimes someone else's data. Here's how I clean it up before I trust it.
Servers: reset the management controller first.
- Dell PowerEdge: the iDRAC can still hold the last owner's users and network settings. Dell's iDRAC reset guide shows how, and on iDRAC7 and iDRAC8 the racadm racresetcfg command removes user and network settings. After a reset, the login is root with either the legacy "calvin" password or a unique password on the pull-out Service Tag, per Dell. Change it right away.
- HPE ProLiant: the iLO 5 System Utilities have a Set to factory defaults option. Older iLO 4 firmware before version 2.53 has a critical authentication bypass, CVE-2017-12542, so update iLO before anything else.
- Then update the BIOS and the management firmware from the vendor's support site, and keep the management port off the internet.
Drives: trust the logs, not the label.
- Check the hours. In January 2025, heise found used Seagate drives sold as new, with up to 22,000 hours on them, while the normal SMART counters looked fresh. On Seagate drives, smartctl -l farm shows the FARM log. Seagate confirmed to heise that SMART values can be reset and that the FARM hours are probably correct.
- Seagate told Tom's Hardware it didn't sell those drives to resellers. Its own refurbished drives are sold as Factory Recertified, with a green sticker, not as new.
- Run a long SMART test and a full read before the drive holds anything you care about.
- Wipe drives before you sell or recycle them. NIST's SP 800-88 Rev. 2 is the standard reference on media sanitization. Alleged (unverified): overwriting an SSD may not reach every flash cell, so use the maker's secure erase or sanitize tool instead.
Network gear: reset and update.
- Factory-reset used switches and routers, then update the firmware before they join your network. On MikroTik, CVE-2018-14847 let attackers read files on RouterOS through 6.42, and CISA lists it as a known exploited vulnerability. MikroTik's advice was to upgrade, change the password and check the config.
- Check that the vendor still ships updates. Gear past end of support won't get fixes for new bugs, so keep it behind your router, never facing the internet.
About "Alleged": a sentence marked Alleged hasn't been checked against a source yet. Treat it as a claim, not a fact. Claims with a link point to their source.
Drafted with AI assistance, fact-checked and approved by RackedPrice.
No affiliate links in this guide. Safety advice shouldn't come with a sales pitch. Last checked Nov 23, 2026. See also: security notes for the gear we track.